Passive Solar
Variable-base degree-day analysis. Solar and internal gains lower the balance temperature, reducing the degree days actually counted — results update live.
Setpoints & gains
Defaults: residential 4 W/m², commercial 8 W/m² (currently residential).
Shading & attenuation
Shading devices
Neighbouring buildings, trees, fences and landforms. Each device is turned into an angular obstruction mask (bearing, angular width, elevation) and tested against the sun path for every 10 minutes of the representative day in each month.
No shading devices yet. Add a neighbouring building, tree, fence or landform and give it a direction, distance and height — the solar gains, heating and cooling results update immediately.
Solar radiation on vertical surfaces
New Zealand (typical) · lat -41.3° · kWh/m²·day
| Month | North | South | East | West |
|---|---|---|---|---|
| Jan | 2.82 | 2.59 | 4.15 | 4.15 |
| Feb | 3.00 | 1.87 | 3.57 | 3.57 |
| Mar | 3.08 | 1.32 | 2.82 | 2.82 |
| Apr | 2.89 | 0.92 | 1.91 | 1.91 |
| May | 2.72 | 0.60 | 1.38 | 1.38 |
| Jun | 2.45 | 0.48 | 1.09 | 1.09 |
| Jul | 2.66 | 0.53 | 1.25 | 1.25 |
| Aug | 2.92 | 0.74 | 1.70 | 1.70 |
| Sep | 3.04 | 1.14 | 2.43 | 2.43 |
| Oct | 2.90 | 1.62 | 3.16 | 3.16 |
| Nov | 2.75 | 2.30 | 3.78 | 3.78 |
| Dec | 2.70 | 2.68 | 4.05 | 4.05 |
Monthly mean daily global horizontal irradiation and air temperature normals — NIWA (CliFlo / SolarView). Vertical-surface irradiation derived with the Liu–Jordan isotropic sky model and the Erbs diffuse-fraction correlation.
Zone solar inputs
| Zone | Glazing m² | SHGC | Solar kWh/yr | Internal kWh/yr |
|---|---|---|---|---|
| Primary zone | 0.0 | 0.00 | 0 | 0 |
Glazing area includes the vision-glass share of curtain wall, window-wall, structural silicone and double-skin facades, counted on every storey. Spandrel-only panels are opaque and admit no solar gain — choose a vision/spandrel average curtain wall to model gains.
Monthly heating: with vs without gains
Solid bar = heating demand with passive gains · grey = without gains (kWh).
Passive solar fraction by zone
Savings summary
| Zone | Base kWh | With gains | Saved | % |
|---|---|---|---|---|
| Primary zone | 0 | 0 | 0 | 0.0 |
| Whole building | 0 | 0 | 0 | 0.0 |
Annual saving
$0
Heating intensity
0.0 kWh/m²·yr
Passive solar fraction
0.0 %
Cooling demand
0 kWh
Validation
Useful gains never exceed the base heating demand
Base 0 kWh; with gains 0 kWh
Passive solar fraction within a physical range (0–90 %)
0.0 % of the gross winter energy balance
Balance temperature stays at or below the heating setpoint
Setpoint 18.0 °C
Heating intensity plausible for NZ housing (< 250 kWh/m²·yr)
0 kWh/m²·yr
Solar gain per m² of glazing below the incident radiation limit
No glazing entered